top of page
Search

NK
Jun 15, 20232 min read
Vibration mitigation of 260 MW Francis turbine and generator by turbine guide bearing gap adjustment
We were engaged to perform vibration measurement and analysis of a 260 MW Francis turbine and generator and recommended a solution to...
357 views
0 comments

NK
Jun 8, 20234 min read
One shot field balancing on 41 MW steam turbine with pipe strain problem
We were engaged to perform vibration measurement and analysis of a 41 MW steam turbine and generator as the excessive vibration amplitude...
207 views
0 comments


RC
Jan 24, 20221 min read
Pre and post outage vibration data collection and analysis
This is mandatory for power generation and petrochemical plants overhaul as vibration data must be collected at before and after overhaul...
94 views
0 comments


RC
Jan 13, 20222 min read
Commissioning support and troubleshooting high vibration problem on a new steam turbine
This is our last job of year 2021 working on a new steam turbine – generator set during commissioning. Unit installation was completed...
112 views
0 comments


RC
Oct 22, 20212 min read
Motion amplification of cooling water pipe
Crack is noticed at cooling water pipe of a large generator which is suspected due to excessive vibration. Motion amplification (MA) is...
65 views
0 comments


RC
Oct 6, 20211 min read
Using multi-channel vibration analyzer with powerbank
I started my career as machinery diagnostics engineer in 1999 when multi-channel vibration analyzer is big size and heavy compared to the...
117 views
0 comments
bottom of page